fbpx

High Frequency Intraoral Dental X-ray

HATCH X-RAY

High Frequency Intraoral Dental X-ray

About HATCH X-RAY

By incorporating Innovative Technology and the latest Dual Microprocessors, Hatch X-Ray has packed the power and intelligence in a number of ways to enhance the convenience of the clinician and patients

  • The unique  shielding technology results in negligible leakage radiation. This ensures that both the patients and clinicians are safely protected from unwanted radiation
  • The sleek design of the X-Ray tube -head coupled with an in-built short cone, enables it to be positioned at any angle and direction with ease to get good images.
  • X-ray of stable and fine quality is produced by the 100kHz digital generator, offering good quality at a minimum dose.
  • Tube head swivel on horizontal plane 540º
About HATCH X-RAY

By incorporating Innovative Technologies and the latest Dual Microprocessors, Hatch X-Ray has packed the power and intelligence in a number of ways to enhance the convenience of the clinician and patients

  • The unique  shielding technology results in negligible leakage radiation. This ensures that both the patients and clinicians are safely protected from unwanted radiation
  • The sleek design of the X-Ray tube -head coupled with an in-built short cone, enables it to be positioned at any angle and direction with ease to get good images.
  • X-ray of stable and fine quality is produced by the 100kHz digital generator, offering good quality at a minimum dose.
  • Tube head swivel on horizontal plane 540º

Share

Smooth and Stable

The smooth drift-free positioner allows you to trigger the exposure from a distance without concern of a shift in Image position during exposure.

Tube-head Beam Limiting Device

Provides 60 kV – 70 kV voltage range (adjustable in 1 kV steps) and 4 mA–8 mA current range (adjustable in 1 mA steps) to reduce exposure times and the amount of radiation absorbed by the patient.

Technical

Specifications

Line Voltage, Tube Potential

100-110V / 230-240V AC,

Single Φ, 60Hz/50Hz

60kV to 70 kV

(In steps of IkV)

Focal Spot

0.4 mm

Tube Current

4to 8 mA

(In steps of 1 mA)

Applicable Documents Federal Regulations

21 CFR, UL

Options

Extension arm options:

Standard 33” or 24”, 15”

Mounting

Single stud mounting,

Two stud mounting

(optional)

Certifications

ISO 13485:2016

MDSAP

Health Canada

Test Standard

UL listed to  Canada standards

Line Voltage, Tube Potential

100-110VAC,

Single Φ, 60Hz

60kV to 70 kV

(In steps of IkV)

Focal Spot

0.4 mm

Tube Current

4mA to 8 mA

(In steps of 1 mA)

Applicable Documents Federal Regulations

21 CFR, UL

Options

Extension arm options:

Standard 33” or 24”, 15”

Mounting

Single stud mounting,

Two stud mounting

(optional)

Certifications

ISO 13485:2016

MDSAP

Health Canada

Test Standard

UL listed to  Canada standards

All About

Hatch X-ray

High frequency Intraoral X-ray with elegant ergonomics, stability and power provides high quality intraoral diagnostic radiography.

Smooth and Stable

The smooth, drift-Free positioner allows you to trigger the exposure from a distance without the concern of a shift in Image position during exposure.

Latest and Advanced Design

By incorporating Innovative Technologies and the latest Dual Microprocessors, Hatch x-ray has packed the power and intelligence in a number of ways to enhance the convenience of the clinician and patients. The smooth and drift-free positioner allows you to trigger the exposure from a distance without the concern of a shift in image position during exposure. The sleek console is designed with a graphical LCD to display exposure parameters modes of operations and self-diagnostic messages.

Ease of use

The sleek design of the X-Ray tube-head coupled with an in-built short cone, enables it to be positioned at any angle and direction with ease to get good images.

SkanSHIELDTM

The unique shielding technology results in virtually negligible leakage radiation. This ensures that both patient and clinicians are safely protected from unwanted radiation.

SkanSAFETM

This precise digital control for X-ray generation eliminates soft radiation. Hatch X-Ray is designed and built to comply with global safety and protection standards ensuring safety of the user and equipment in the entire operating range.

Frequently asked questions (FAQ)

The Main Components of a Dental Xray Machines are:

  • Tube Head: The Tube Head consists of an anode-cathode filament system It functions as a specific energy converter, receiving electrical energy and converting it into x-radiation and heat.
  • This very specific energy conversion takes place in the x-ray tube. The X-Ray tube consists of
    • A control PCB: It controls the energy conversion.
    • Tube housing: It is fitted with a Position Indicating Device (PID)which X-ray passes through cooling oil: to control and protect from the heat while generating the X-Ray tube cover
  • Scissor Arm: The tube head is mounted on the scissor arm and easily can fix the tube head positioning to the patient
  • Extension Arm: It determines the Max tube head reaches the patient
  • Control Console: The Control Console is the user interface with a display Module. The user can adjust the parameters and select different programs through the console unit

 

Power generating (High Voltage generator) PCB: the Power PCB generates the high voltage and it delivers to the tube head through a set of Cables (communication interface cables)

  • The Tube current mA: The flow of electrons from the cathode to the anode in the X-Ray tube and the measuring unit is mA
  • The Kilovoltage Peak KVp: A high voltage potential measured in KVp. It will determine the quality and the intensity of the image. Usually, it will be between 60-70 KVp for dental Xrays.
  • The exposure time: Usually it will be measured in ms , the maximum up to a few Sec

 

3: What PPE should be used when taking and processing dental X-rays?

The main PPE is a lead apron that covers the neck and the body. Also PPE like gloves,

eye safety glass, Mask etc.

  • Hatch X-Ray can be fix vertical as well as horizontal positions without any extra parts.
  • Hatch X-ray is a high-frequency Dc intraoral Xray it creates high-quality images.
  • Hatch Xray have a feedback circuit which will display the exposed factores on the
  • display. It can make sure the delivered anergy to the patient.
  • Hatch X-Ray can select the KVp And mA by step of 1 unit. It can avoid unwanted radiation
  • to the patient.
  • Hatch Xray can set a wide range value of ms from 40-3500ms.
  • The standard extension arm can reach up to 80”(203mm).

            Custom modes are available 

            3 different extension arm lengths(15”,24” and 33”)

Yes, Hatch X-Ray is registered with  Health Canada

All kinds of technical support for troubleshooting as well as installation procedure

through in-person and telephonic.

  • Pre Installation setup questions: Hatch Xray has a preinstallation template. It

provides all information to prepare for the installation

  • Exposure Parameters questions: The User Manual provides all kinds of parameter

selection.

  • Control console button explanations: the user manual provides all the console keys

explanation with images .

Have a question or interest in buying a product